SCALE X

Pages SCALE_1 … SCALE_8 (PageID 10 … 17). The ID column is the parameter_id you pass in a GET_PARAMETER request.

ID Parameter name TYPE Read Write Default value Description
0 SCALE_PARAMETER_COUNT Uint32 0 Number of parameters on this page
7 MULTIRANGE_MAXIMUM_WEIGHTS Float32 array 0 Scale capacity per range. Calculated from divisions × intervals
13 TEST_MODE_10X_RESOLUTION Bool False Show the weight at ten times the resolution, for service use
18 ZERO_OFFSET Float32 0 Current zero offset
49 EVENT_COUNTER_WEIGHT_OVERLOAD Uint32 0 Counter of scale overloaded
57 CAL_PROGRESS_BAR Uint32 0 Progress of a running calibration
58 TILT_ANGLE_X Float32 0 Current tilt angle in X direction in degrees
59 TILT_ANGLE_Y Float32 0 Current tilt angle in Y direction in degrees
61 LOAD_CENTER_POINT_X Float32 0 Current load center point on X axis
62 LOAD_CENTER_POINT_Y Float32 0 Current load center point on Y axis
63 WIM_COMPLETION_TIMEOUT Uint32 How long a weigh-in-motion measurement may take before it is abandoned
64 ENABLE_LEVEL_ERROR Bool True Enable level error when scale is tilting over 3 degrees
65 ZERO_SETTING_RANGE_PERCENTAGE Float32 How far from zero SET_ZERO is still accepted, in % of capacity
67 FORK_LENGTH_MM Uint32 Fork length in mm, used for the load centre calculation
69 LOAD_CENTER_THRESHOLD Float32 How far off centre a load may sit before the weight is refused
70 TARE_PRESET_INDEX Uint32 0 Index of the tare preset currently applied. 0 is the manual tare
71 TARE_PRESET_NAMES String array Names of the stored tare presets
72 TARE_PRESET_VALUES Float32 array Weights of the stored tare presets

Note

The tare preset list is read-only through the parameter system. Manage it with the CREATE_TARE_PRESET / UPDATE_TARE_PRESET / DELETE_TARE_PRESET requests, and apply an entry with SET_PRESET_TARE.